The following summarizes the contents of ASTM C and key components of the test methods used to determine relative freeze thaw durability. This does not. ASTM C Standard Test Method for Evaluating the Freeze-Thaw The following summarizes the contents of ASTM C and key components of the test. Buy ASTM C Standard Test Method for Evaluating the Freeze-Thaw Durability of Manufactured Concrete Masonry Units and Related Concrete Units.

Author: Dakus Turn
Country: Bahrain
Language: English (Spanish)
Genre: Travel
Published (Last): 23 September 2010
Pages: 397
PDF File Size: 3.16 Mb
ePub File Size: 18.39 Mb
ISBN: 622-4-87100-547-9
Downloads: 55000
Price: Free* [*Free Regsitration Required]
Uploader: Arashilrajas

In the case of a unit with an exposed architectural or other nonplanar surface, cut the coupon from another flat molded surface ideally as far as possible from the architectural or other nonplanar face and in no case less than 2 in. Do not saw-cut test specimens from d1262 that have been previously oven dried. The following summarizes the contents of ASTM C and key components of the test methods used to determine relative freeze thaw durability.

Referenced Documents purchase separately The documents listed below are referenced within the subject standard but are not provided as part of the standard. Immediately rinse the specimen with water if the specimen is tested in saline solution, use saline solutiontorinse the specimen usinga squeeze bottle,being careful to collect in the specimen container the rinse water or saline solution and all loose particles from the specimen. Work Item s – proposed revisions of this standard.

This summary attempts to provide the information which is most commonly used, but Allan Block does not claim that all information contained in the standard is represented. Replace the specimen in the container. The units shall be free from visible cracks or structural defects. Remove a single specimen from its container. Pour the test solution from the specimen container through the filter paper to collect the residue spall from the test specimen.

  BIBLIOTHECA CHEMICA CURIOSA PDF

Remove the specimen from the container, pourthe rinse water or saline solution through the filter paper, and rinse the specimen container until all residue spall in the specimen container is collected on the filter paper. Related concrete units include units such as hollow and solid concrete masonry units, concrete aatm, and concrete roof pavers.

Open containers to visually inspect the condition of the specimens and to adjust the test solution level to comply with 7.

Using fingertips and a squeeze bottle, remove loose particles from all surfaces of the specimen, again being careful to collect all rinse water or saline solution and loose particles in the specimen container.

Zstm Version s – view previous versions of standard. Note 6 – Split-faced surfaces are the most common surfaces used to provide an architectural appearance to segmental retaining walls.

It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. This does not provide a comparison to field performance 1c262 a systematic approach to testing.

Do not c12262 immerse coupons in water. Link to Active This link will always route to the current Active version of the standard. However, other means could be used to obtain similar architectural effects like tumbling, grinding, and slumping.

Rinse the residue from specimens tested in saline solution three times with water to remove any soluble salt. Close the container lid tightly and store the container on a level surface in laboratory air as defined in 6. Immediately following saw-cutting, remove loose particles and residue from the coupon by rinsing in tap water and brushing with a soft bristle brush.

  COURS DEVELOPPEMENT INFORMATIQUE OFPPT PDF

ASTM C Standard Specification for Segmental Retaining Wall Units

Each specimen shall bemarked with a unique identification number on the non-molded surface of the specimen. The testing laboratory performing this test method should be evaluated in accordance with Practice C The values stated in each system may not be exact equivalents; therefore, v1262 system shall be used independently of the other.

Related concrete units include units such as hollow and solid concrete masonry units, concrete brick, and concrete roof pavers. Do not subject test specimens to oven-drying prior to completion of freeze-thaw testing. Report these values for each specimen as well as the average of the specimens tested.

Product Specifications

Combining values from the two systems may result in non-conformance with this standard. Cut the coupon from the exposed surface of the unit as the unit is used in service atm the exposed surface is an architectural or other nonplanar surface see Note 6. A copy of the full standard is available upon request. Consider any pieces that separated from the specimen as part of the residue.

Asstm not pour test solution directly onto the specimen. Some values have only SI units because the inch-pound equivalents are not used in practice. Where the coupon thickness is less than 1.