ASTM D1267 PDF

Home  /   ASTM D1267 PDF

This standard is issued under the fixed designation D ; the number immediately 1 This test method is under the jurisdiction of ASTM Committee D02 on. ASTM D Standard Test Method for Gage Vapor Pressure of Liquefied Petroleum (LP) Gases (LP-Gas Method). VAPOR PRESSURE ASTM D TECHNICAL SPECIFICATIONS. VAPOR PRESSURE CYLINDER UPPER CHAMBER. Stainless steel upper chamber with .

Author: Nall Sakree
Country: Mexico
Language: English (Spanish)
Genre: Art
Published (Last): 4 December 2014
Pages: 298
PDF File Size: 4.59 Mb
ePub File Size: 17.3 Mb
ISBN: 700-5-73735-901-5
Downloads: 29458
Price: Free* [*Free Regsitration Required]
Uploader: Zunos

Looking for a specific close-up?

Note that Nitrogen and Oxygen were added ast, the component list in order to be able to perform air saturation in the sample. The sample is transferred to a test apparatus consisting of two interconnected liquid and vapor chambers and equipped with a suitable pressure-measuring device. The Reid Vapor Pressure is defined as the vapor pressure of a mixture as it was measured according to the experimental method depicted in the ASTM Da standard method [3].

Maximum vapor pressure limits for gasoline are legally mandated in some areas as a measure of air pollution control. VMGSim calculates the vapor pressure by flashing the mixture of interest using a vapor fraction equal to zero at the temperature specified in the stream that contains the mixture.

Petroleum Gas Sampling Cylinder. Product Description The K Reid Vapor Pressure Cylinders are polished stainless steel test cylinders for vapor pressure tests of liquid petroleum products, volatile crude oil and liquefied petroleum gas LPG. Enter product namemake or model.

ASTM D1267

Referenced Documents purchase separately The documents listed below are 1d267 within the subject standard but are not provided as part of the standard. The method is very similar to Da but in this case the air saturation is not required. These properties are obtained from flash-based calculations that depend on the selected property package.

  DIGITAL DESIGN BY MORRIS MANO AND MICHAEL CILETTI PDF

These properties are new to VMGSim and are labeled as: Since most vapor pressures are reported in absolute pressures, most observers expect the Reid Vapor Pressure to follow this norm. The following pure components were added to the components list: Pharmaceutical laboratory apparatus stability chambers, tablet disintegration, tablet dissolution, tablet hardness, V-blenders, Both N 2 and O 2 must be present in the component list from the property package for the proper use of this method.

The calculated RVP value is Units Like in the Da method, there is confusion about the units used for this property. The following link provides additional information from the instruction manual or original manufacturer’s brochure.

Comments on Vapor Pressure If True or Reid Vapor Pressure values are calculated for oils or its fractions, the oil pseudo-components should be modeled as accurately as possible with respect to the oil characterization data.

The vapor pressure of a mixture is commonly defined as the pressure where the first bubble of vapor is formed at a given temperature but there are other definitions based on standardized experimental measurements or correlations. Right-click to open the PDF in a new window or download it: Gas Conditioning and Processing 7 th Ed.

ASTM D – Parkes Scientific Canada

The standard method establishes that the analyzed mixture must be placed in a sample container kept in a cooling bath at 32 F. Historical Version s – view previous versions of standard. Home Client Login Register. Lab Equipment for Sale: All examples were calculated using VMGSim 9. If True or Reid Vapor Pressure values are calculated for oils or its fractions, the oil pseudo-components should be modeled as accurately as possible with respect to the oil characterization data.

Seta Reid Vapour Pressure Bath for ASTM D, ASTM D, ASTM D, IP , IP , IP 69

Calculations were done using the Advanced Peng-Robinson property package. Examples of these definitions are: General Use laboratory apparatus balances, baths, blenders, centrifuges, chart recorders, freezers, fume hoods, furnaces, glassware washers, glove boxes, mixers, moisture testing, ovens, pumps, shakers, vacuum equipment, water purification Previous calculations in VMGSim did not take into account the air saturation, which caused the results to be lower.

  KWML MASTERY PDF

This test method is used to determine the vapor pressure at The Reid Vapor Pressure is an important d12267 of gasolines and jet fuels and it is used as a criterion for blending of products. The sample is similarly saturated with air at 32 F and the vapor pressure form the system is also read from a pressure-measuring device attached to the apparatus. The ASTM D standard method follows a similar procedure than the Da method, except that the ratio of the volume of the vapor chamber to the volume of the liquid chamber is 2.

Campbell [5] reports that the air was ashm from the cell where the RVP was measured. Reid Reid Vapor Pressure Bomb.

ASTM D1267 LPG/Astm D323

For determination of the vapor pressure of liquefied petroleum gases, refer to D2167 Method D or Test Method D True Vapor Pressure F This property is similar to the Vapor Pressure calculation except that the flash calculation is performed at a specific temperature of F.

This example has been done using the Advanced Peng-Robinson property package. The air saturation can be activated through the same check box as in the Reid Vapor Pressure calculation. This is no longer the case since VMGSim 9. Once this was done, a close match between calculated and experimental values of the distillation curve was obtained.