Uniden Bearcat xlt Scanner Manual. Document for Uniden Bearcat xlt Scanner Manual is available in various format such as PDF, DOC. [PDF] [EPUB] Bearcat Xlt Scanner Manual [PDF]. Book file PDF easily for everyone and every device. You can download and read online. Scanner Manual PDF or Read Uniden Bearcat Xlt Scanner Manual PDF on The Most Popular. Online PDFLAB. Only Register an Account.

Author: Aranos Fenrilkis
Country: Montenegro
Language: English (Spanish)
Genre: Personal Growth
Published (Last): 8 August 2005
Pages: 455
PDF File Size: 17.97 Mb
ePub File Size: 11.98 Mb
ISBN: 392-1-20973-557-9
Downloads: 35419
Price: Free* [*Free Regsitration Required]
Uploader: Tojazshura

Scroll to the quick key number or. There may be 3 or 4 frequencies assigned as primary or alternate control channels but only one control channel will be active at a time. Once you have your Systems built, systems options configured, trunking system Sites Createdand Site Options configured, you can create your groups. Turn to adjust the squelch. To check for a repeater frequencypress Hold to hold on the frequency. Press Hold again to resume.

PRI appears in the display when you select this mode.

Set Lockout determines whether a site will be scanned or not even if the quick key for the site is turned on. The scanner stores the ID into a created channel group called ‘ Qck Save Grp ‘ with no quick key assigned and you will be at the ‘ Edit Channel ‘ menu to complete the settings for the new channel.

The Close Call feature works well for locating the source of strong local transmissions such as mobile and handheld two-way radios in areas with no other strong transmission sources. Set Lockout As you near your target location, an alert sounds at 10.

The screen will display “PRI” when on, just press the button to turn it off. To start a ‘Quick Search’ at the current frequency turn the scroll control then press Hold. You could use this feature to give you quick, single-press access to your favorite systems. Dynamic Memory has its drawbacks because you have to build everything then program it.

  HAL FOSTER LA POSMODERNIDAD PDF

uniden bearcat xlt scanner manual

Conventional Display Mode 1. To exit CC only p ress Scan. Trunking systems in general allocate and use fewer frequencies among many different users. The display will show the Tone-Out name, channel numberand tone settings. Set Start-up Key manaul you to turn on the scanner with the system enabled for scan using the Startup Configuration. To move bearrcat cursor to the rightpress 6. Turn to scroll to a menu item in Menu Mode.

Once you have your Systems built, systems options configured, Sites Created for trunking systemsSite Options configured, and Groups Createdyou can finally program your channels. The scanner will save the frequency into a created group called ‘ Qck Save Grp ‘ in a created system called ‘ Qck Save Cnv Sys ‘ with no quick key assigned and you will be at the ‘ Edit Channel ‘ menu to complete the settings for the new channel.

Use what works best for you. Press and hold 7 Att for global attenuation. Select ‘ All Range ‘ to be alerted regardless of your direction of approach.

Edit Channel creates channels and edits channel options. See Programming Trunking Systems. What state, county, city, agencies, etc.

Read uniden-bearcatxlt-scanner-manual

Then see Storing a Displayed ID. The stock whip isn’t fabulous. Rotate the SQ knob counter-clockwise all the way then clockwise manusl the noise stops, then one notch more. Yes – the scanner immediately returns to the control channel when it detects the end code. All systems, sites, or search ranges that do not have a startup key assigned will be scanned the way they were when you last turned off the scanner.

  ETIMOLOSKI RECNIK PDF

If the scanner detects the transmission on the output frequency, it beeps and ‘ Repeater Found ‘ appears, and it remains on the output frequency until transmissions end. manuual

To store a frequencypress Hold to hold on the frequency. You can also configure the scanner to sound an alert tone and flash a light when you reach the radius entered here. There is no ‘per channel’ delay; you must set the delay for the whole system all groups, all channels. If the frequency has not been stored, it stores the frequency into a created system called ‘ Close Call ‘ and a created group named ‘ Found Mnaual ‘ then resumes searching.

At ‘ Select Site Type ‘: This trunking scanner trunktracks the following types of systems: No to view the trunking activity indicators when scanning a trunked site in Scan Mode.

800 xlt setup help

These range distances are also automatic and fixed. With this scanner, you select conventional ‘Systems’ or trunking ‘Sites’ to scan that have channel ‘Groups’ stored within the ‘Systems’. All settings and data saved on the Slave scanner will be erased. You can also temporarily lockout cancel any combination of these alerts. See Max Auto Store first to set the maximum number of hits the scanner maanual store.

Most people can get everything they scan into the scanner. If you select 0 for trunking sites, the scanner stays on the site for at least 1 second. Click here to visit Scanner Master. Make sure the power is turned off.